Download Release NotesUpdates
Fixed figures 2.2, 2.4
New EMUS CAN Current sensor added
Added BMS Failure Output
Removed Clustered Series connection
New charging model explanation
Added chapter how to configure SOC Kalman & Coulomb
Removed iOS App (upgrade delayed)
Minor fixes
Removed iOS App (upgrade delayed)
New format, grammar and spelling corrections
2021-01-28 15:32:49
Download Release Notes2021-05-13 16:18:53
Download Release NotesKnown issues:
When tabs that were dragged out of the main window are closed, the whole Control Panel can also close
Pulses per Distance Unit field is unused for now as Speed Sensor input is not functioning yet
GPI, GPO selection list not fully correct
User interface does not allow to enter high accuracy PSU divider value
Min User SoC range can be set higher than Max. Then user SoC is shown as 0% or 100%
2024-09-02 16:57:53
Download Release Notes#424 Added new CAN devices versioning
#1105 Tab docking issue fix
#1078 Clustered system protections/warnings delay parameter fixes
#972 CS030A can be replaced without a Re-discover process
#975 Connecting CS030A & ISA simultaneously, leads to a discovery issue
#1070 2.15.0 Incorrect information about chargers in Slave's Control Panel
#1092 String Voltage Equalization and Current deviation were not tested
2021-09-24 17:13:51
Download Release NotesKnown issues:
Non-Clearable statistics not saved
BMS might reset during charging stages, reset period could be 1-2hrs
Wireless connectivity module only transmits data to a connected device, receiving will be added in a later firmware update
Main clock can drift and fall behind up to couple of minutes per day
Speed Sensor input is not functioning yet
No SoC PWM output functionality yet
Cell Wire Break protection deactivation delay is not as set
BMS reset needed after cell count configuration to clear wire break protection/indication
CAN Broadcast Period not accurate
Each Call Value not broadcasted
Charging restarts on max cell voltage drops below restart value
Out of boundary current is indicated as measured, not as incorrect reading
Wire break indicated correctly not in all cases
Version 2.8.4Known issues:
Wireless connectivity module only transmits data to a connected device, receiving will be added in a later firmware update
Main clock can drift and fall behind up to couple of minutes per day
Speed Sensor input is not functioning yet
No SoC PWM output functionality yet
Cell Wire Break protection deactivation delay is not as set
BMS reset needed after cell count configuration to clear wire break protection/indication
2024-06-07 10:35:14
Download Release Notes2024-06-07 10:52:11
Download Release Notes2024-09-02 17:02:55
Download Release Notes---
#1078 Wrong delays of Master/Slave protections, reductions and warnings
#1225 Clustered system default config fix
#972 CS030A can be replaced without Re-discover process
#975 Connecting CS030A & ISA at the same time leads to discovery issue
#1070 2.15.0 Incorrect information about chargers in Slave's Control Panel
#1092 Not tested String Voltage Equalization and Current deviation
2024-04-05 13:59:05
Download Release Notes2024-08-09 17:26:25
Download Release Notes2019-02-11 17:36:44
Notifications of End of Life announcement of EMUS products . For full history list of EoL notifications please press "Show all Versions" at the bottom.
Download2019-02-11 17:37:55
Notifications of EMUS products price changes. For full history list of price update notifications press "Show all Versions" at the bottom.
Download2019-10-01 08:20:57
Detailed description of G1 BMS CANopen Object Dictionary
DownloadOur company specialists are ready to provide technical assistance and consult in matters related with use of our products. In order to attain the best service quality, we kindly ask you to fill the contact form by clicking the button below.