EmusBMS
For complete BMS system, below components are necessary:
Control Unit 24V G1 BMS Control Unit CS030A EMUS CAN Current Sensor EMUS Loop type current sensor G1 Loop Style Dual Range Current Sensor

EMUS Centralized Cell Group Module is a battery cells communication adapter (or “Slave unit”) equipped with two CAN connectors for easy BMS system assembly and integrated proprietary EMUS software allows data transfer within 100ms frequency. It also have 5 external temperature sensors to monitor ambient temperature.
Each CCGM is capable of managing from 6 up to 16 lithium cells and total of 25 CCGM units can be connected in series, parallel, or mixed topology.

  • Cell voltage measurement
  • External 5 temperature sensors
  • Balancing of the cells, 400 mA per each cell
  • 2 CAN connectors

Applications:

  • Energy Storage Systems (ESS)
  • E-mobility applications
  • Mobile Energy Storage Systems

Specifications:

  • Number of cells: 6 – 16
  • Balancing current: 420mA
  • Supply voltage: 12 – 67V
  • Temperature sensors: 5x
  • Two CAN connectors;
  • Isolation between communication and battery side 850V*
  • Operating temperature: -40 to +80
  • Dimensions: 90x61x16.5
  • Communications bus: CAN
  • Mounting holes: M4

* According to standard IEC 60664-1:2020. Direct contact between CCGM024B’s heatsink and conductive surface without potential might decrease isolation endurance under environmental conditions classified as Pollution level 2 or superior.

Ordering Information:

Please use part numbers below for ordering the products

Part number Description Package Contents

CCGM024B

EMUS Centralized CAN Cell Group Module

1x EMUS Centralized CAN Cell Group Module

CCGM024B+Q

EMUS Centralized CAN Cell Group Module with quick start kit

1x EMUS Centralized CAN Cell Group Module

Quick connection kit contains:
ETS05-45, 45cm temperature sensors kit
CH02-45, 45cm cells connection kit

Manual:

G1 BMS User Manual 2.12.2

2024-11-25 19:04:52

Download Release Notes

Firmware:

G1 Centralized CAN Cell Group Module (High Voltage) firmware v2.9.8_v2.9.9_LTO (CCGM024)

2024-06-07 10:52:11

Download Release Notes

Datasheets:

G1 Centralized CAN Cell Group Module (024) data sheet CCGM024B

2024-12-03 16:00:30

Download

3D Design Files:

High Voltage Centralized Cell Group Module STEP File CCGM024B

2024-02-23 21:56:25

Download

Get samples and test EMUS BMS!

+370 686 45554
On workdays 9 -18 (GMT +3)

Request and proposals
sales@emusbms.com

Service calls
Support@emusbms.com