New/Improved: Default parameter values set for Li-Ion chemistry. Added Cell information "Poll Period" as configurable parameter. Introduction of configurable Warnings with activation and deactivation delays. Improved current sensor calculations precision. New SOC/SOH estimator algorithm User SOC selection range, "Usable range". Flexible configuration of charging safety limit and charging intensity ramping up and down. Implemented "Current sense in range indication" pin-function. Implemented 'Power Supply Unit' under-voltage sensing and indication feature, that allows user to configure system that monitors its power supply voltage and indicates when under-voltage threshold is reached. Allows user to select battery charging level at which charging is stopped preventing battery to reach its maximum SoC. Battery contactor can be controlled by "PF4 Ignition Key Input" pin-function, when enabled in Control Panel. CANOpen limited implementation for reading SDO values along with Object Dictionary. Victron inverter CAN control integration. Lion CAN charger control integration. Brusa6 CAN charger control integration. Shinry CAN charger control integration. Ingeteam Play inverter integration. Fixes: Charger Enable: Off when charger is not detected. Cell Collection time out. Pre-charge timer reset while using ignition control. Periodic data broadcast to CAN. Master/Slave Protection triggering. Pre-Heating Enable fix when Charging. Password timeout and lockout after incorrect password. CAN message filtering improvement. Changing PinFunction to "PF0 No Function" Disables previous set pin, if enabled. "PF10 Charger Enable Output" does not switching off during No Cell Communication Error. Balancing fix In "No cell communication" status. SOC value estimation. Added additional balancing boundary check for early balancing in cases when few cells are much higher than average. Partial data received error Under some conditions all battery cells are balancing together at the same time. Duration of contactor pre-charge. Pre-Charge activation from "PF4 Ignition Key Input". CGM communication retry mechanism. Wrong cell numbers in the statistics if using CGM's. External temperatures occasional timeout. Master/Slave communication issues. Incorrect calculation of average and total voltage values until "BV2" sentence is requested. Using hard hysteresis when calculating "Set charging current". When actual cell voltages are way above "Fully charged voltage" parameter value and protection thresholds are not reached, system sets value for "Set-voltage" parameter lesser than "Total battery voltages". Climate control heater active output persists in case of over-heat. Problem with the charge status set voltage. It is showing very low voltage(or high voltage, if this is an comma error). String current deviation alarm while only one string is set. Known issues: Level access does not allow to clear events/statistics. Battery Charge/Capacity not recalculated/displayed in legacy firmware. PSU input/output does not function correctly. Charge/Discharge overcurent warning deactivation delay. Pack Voltage Deviation Warning activation. Emergency ON does not use pre-charge. M/S parallel String voltage equalization operates once, not at every connection. No cell communication (protection) with CGM having over 100 and over 200 cells. Analog Controlled charger does not reduce current. Level1 required for Level2 access.