Test EMUS BMS risk free!
Please refer to documentation manuals and datasheets below for our products information. All related apps, software and firmware are listed as well.
2020-12-15 12:50:29
G1 BMS system user manual which documents the whole BMS system components, connectivity, configuration, monitoring, troubleshooting and much more.
Download Release NotesAdded new chapters:
2.1.3 Centralized Cell Monitoring
2.1.4 Temperature measurement
2.3.2 Integrated SOC/SOH estimator (gen1 algorithm)
2.3.2.1 SOH algorithm
2.7 Warnings
4.1 EMUS BMS Control Panel
4.9 Charging process
4.14 SOC Estimation
4.14.1 SOC legacy adjustment algorithm
4.14.2 SOC/SOH estimator (gen1 algorithm)
4.14.2.1 Tuning parameters
4.14.2.2 Cell model reference settings
4.14.2.3 SOC-OCV dependency curve of cell
4.14.2.4 SOC dependency on temperature
Other:
All products technical information has been transferred to separate datasheet documents
2018-11-11 19:51:20
Download Release Notes2019-10-01 08:20:57
Detailed description of G1 BMS CANopen Object Dictionary
Download2018-12-10 10:31:23
Download Release Notes2018-12-10 10:34:09
Download Release Notes2021-01-05 14:07:31
Download Release NotesFixes:
Fix to discovered CGMs showing incorrect number of cells
Known issues:
Battery Charge/Capacity not recalculated/displayed in legacy firmware
PSU input/output does not function correctly
No warning/message when password is typed in incorrectly more than 10 times
Pin inversion on some pin functions
2020-12-15 17:58:34
Download Release NotesNew/Improved:
Refreshed overall look and feel of the GUI
Added more progress bars to be more informative of an ongoing process
Introduction of configurable Warnings with activation and deactivation delays
New Pin Function support
Added support for new SOC/SOH estimator algorithm
Added support for user SOC selection range, "Usable range"
Added support for Master/Slave configuration
Added support for user to select battery charging level at which charging is stopped preventing battery to reach its maximum SoC
Added option to maually choose a COM port and connect to the Control Unit
Added support for new CAN devices
Added CGMs mapping tab for manual CGM configuration
Fixes:
Communication with CAN devices (updating/cofiguration)
GUI issues
Updating Control Unit
Loading parameters to/from Control Unit
Loading SOC curve to Control Unit
Serial COM port scanning, selection fix
Known issues:
Battery Charge/Capacity not recalculated/displayed in legacy firmware
PSU input/output does not function correctly
No warning/message when password is typed in incorrectly more than 10 times
Pin inversion on some pin functions
2019-05-28 09:26:19
Download Release NotesFeatures
EMUS Centralized CAN Group Modules support
Added update and configuration support for EMUS Centralized CAN Group Modules.
Enhancements
Several additional error status reports added for update procedure.
Now when parameters which are unknown to Control Unit are requested, instead of endless polling of these parameters the cycle will break after one iteration of parameter set request.
Fixes
During CAN Group Modules configuration procedure Control Panel sometimes could crash.
During Control Unit firmware update procedure Control Panel sometimes could crash.
2019-01-17 15:25:15
Download Release Notes2018-02-13 20:34:29
Download Release Notes2017-08-25 00:04:55
Download Release Notes2017-06-19 20:21:53
Download Release Notes2017-04-21 20:16:51
Download Release Notes2017-04-07 20:14:52
Download Release Notes2020-05-26 18:39:31
Download Release NotesFixes
Value of 'Total Voltage' in Layout #4 was displayed incorrectly above 655 volts
2020-03-03 14:34:49
Firmware for EMUS BMS Mini devices.
Download Release NotesFeatures
Added CANopen protocol support for Serial peripheral
Added Delta-Q charger support
Added CANopen client support
Added CiA 418 PDO support
Added pin function status report
Added power saving modes (storage - deep, automatic - light)
Added internal operational limits (current, temperature)
Added "Not detected battery" EMCY object
Added 'Storage mode' pin function
Improved battery detection mechanism
Added Current sensing configuration parameters
Fixes
Fixed repetitive toggle between charging stages
Sometimes charging was impossible until any protection recovers
Sometimes protectiosn were not triggered properly
Fixed CANopen OD 0x6000
Sometimes protection was triggered twice resulting in registering duplicated protection
When all emergency error codes are cleared BMS did not switch from pre-operational to operational state.
CANopen OD 0x1001 incorrect update
Reset to factory defaults was not working correctly
Inverting GPO pin function did not work correctly
'Protection reset' pin function could be triggered once
Fixed initial notification of not detected batteries when system starts-up
When system starts contactor pre-charge is not activated before closing contactor
2019-02-11 17:36:44
Notifications of End of Life announcement of EMUS products . For full history list of EoL notifications please press "Show all Versions" at the bottom.
Download2019-02-11 17:37:55
Notifications of EMUS products price changes. For full history list of price update notifications press "Show all Versions" at the bottom.