Search:

G1 CAN Cell Group Module

EMUS BMS CAN Cell Group Module

Description:

Emus BMS Can Cell Group Modules are cell communication adapters for interfacing the main controller and separate parts of a battery pack, that enables Emus battery management system to serve large battery packs and systems of multiple cell strings connected in parallel. Each Can Cell Group Module is equipped with a special isolated serial interface for connecting to a group of Emus Cell Modules, and a robust CAN v2.0 A/B interface for connection to the main controller.

Specifications:

Each CAN Cell Group Module supports up to 254 cells;
Galvanic isolation 2kV (cell communication serial interface);
Operating voltage: 9.6V÷36V;
Operating temp.: -40°C ÷ +80°C;
Dimensions: 66.3x50x15mm;
Wire length:
– Cell communication 0.5m;
– CAN bus 1m (with connector);
Mounting hole: M3.5

Large, high voltage, series connected battery packs. High capacity battery systems of multiple cell strings connected in parallel. Applications with high levels of electromagnetic noise.

Ordering Information:

Please use part numbers below for ordering the products

Part numberDescriptionPackage Contents

CGM020A

G1 CAN Cell Group Module

EMUS BMS CAN Cell Group Module – 1pcs.
CAN cable – 1 m.
Ring Terminal M8 – 3 pcs.

Manuals:

G1 BMS User Manual 1.2.1

2018-11-11 19:53:18

G1 BMS system user manual which documents the whole BMS system components, connectivity, configuration, monitoring, troubleshooting and much more.

Download Release Notes

Firmware:

G1 CAN Cell Group Module firmware 1.3

2018-11-13 10:12:05

Download