G1 Can Cell Group Modules are cell communication adapters for interfacing the main controller and separate parts of a battery pack, that enables Emus battery management system to serve large battery packs and systems of multiple cell strings connected in parallel. Each Can Cell Group Module is equipped with a special isolated serial interface for connecting to a group of EMUS Cell Modules, and a robust CAN v2.0 A/B interface for connection to the main controller.

Specifications:

Each CAN Cell Group Module supports up to 254 cells
Galvanic isolation 2 kV (cell communication serial interface)
Operating voltage: 9.6 V…36 V
Operating temp.: -40 °C … +80 °C
Dimensions: 66.3 x 50 x 15 mm
Wire length:
– Cell communication 0.5 m
– CAN bus 1 m (with connector)
Mounting hole: M3.5

Applications:

  • Large, high voltage, series connected battery packs
  • High capacity battery systems of multiple cell strings connected in parallel.
  • Applications with high levels of electromagnetic noise.