2023-11-13 11:19:54
Download Release NotesUpdates
Obsolete products removed from manual and uploaded new products versions
New Clustered naming and illustration
Chapter 3.10 wiring corrected
2021-08-20 10:34:22
Download Release NotesAdded new chapters:
2.1.3 Centralized Cell Monitoring
2.1.4 Temperature measurement
2.3.2 Integrated SOC/SOH estimator (gen1 algorithm)
2.3.2.1 SOH algorithm
2.7 Warnings
4.1 EMUS BMS Control Panel
4.9 Charging process
4.14 SOC Estimation
4.14.1 SOC legacy adjustment algorithm
4.14.2 SOC/SOH estimator (gen1 algorithm)
4.14.2.1 Tuning parameters
4.14.2.2 Cell model reference settings
4.14.2.3 SOC-OCV dependency curve of cell
4.14.2.4 SOC dependency on temperature
Other:
All products technical information has been transferred to separate datasheet documents
2020-12-15 12:50:29
Download Release NotesAdded new chapters:
2.1.3 Centralized Cell Monitoring
2.1.4 Temperature measurement
2.3.2 Integrated SOC/SOH estimator (gen1 algorithm)
2.3.2.1 SOH algorithm
2.7 Warnings
4.1 EMUS BMS Control Panel
4.9 Charging process
4.14 SOC Estimation
4.14.1 SOC legacy adjustment algorithm
4.14.2 SOC/SOH estimator (gen1 algorithm)
4.14.2.1 Tuning parameters
4.14.2.2 Cell model reference settings
4.14.2.3 SOC-OCV dependency curve of cell
4.14.2.4 SOC dependency on temperature
Other:
All products technical information has been transferred to separate datasheet documents
2020-03-17 23:03:52
Download Release Notes2020-01-24 12:52:01
Download Release Notes2018-12-07 15:25:07
Download Release Notes2018-11-11 19:53:18
Download Release Notes2021-01-28 15:32:49
Download Release Notes2021-05-13 16:18:53
Download Release NotesKnown issues:
When tabs that were dragged out of the main window are closed, the whole Control Panel can also close
Pulses per Distance Unit field is unused for now as Speed Sensor input is not functioning yet
GPI, GPO selection list not fully correct
User interface does not allow to enter high accuracy PSU divider value
Min User SoC range can be set higher than Max. Then user SoC is shown as 0% or 100%
2023-07-28 17:03:00
Download Release Notes#RND-40 CAN device speed change issues
#RND-39 CCGM detection issue
2021-09-24 17:13:51
Download Release NotesKnown issues:
Non-Clearable statistics not saved
BMS might reset during charging stages, reset period could be 1-2hrs
Wireless connectivity module only transmits data to a connected device, receiving will be added in a later firmware update
Main clock can drift and fall behind up to couple of minutes per day
Speed Sensor input is not functioning yet
No SoC PWM output functionality yet
Cell Wire Break protection deactivation delay is not as set
BMS reset needed after cell count configuration to clear wire break protection/indication
CAN Broadcast Period not accurate
Each Call Value not broadcasted
Charging restarts on max cell voltage drops below restart value
Out of boundary current is indicated as measured, not as incorrect reading
Wire break indicated correctly not in all cases
Version 2.8.4Known issues:
Wireless connectivity module only transmits data to a connected device, receiving will be added in a later firmware update
Main clock can drift and fall behind up to couple of minutes per day
Speed Sensor input is not functioning yet
No SoC PWM output functionality yet
Cell Wire Break protection deactivation delay is not as set
BMS reset needed after cell count configuration to clear wire break protection/indication
2023-07-28 17:10:57
Download Release Notes2023-06-28 16:21:51
Download Release Notes#7819 Remaining distance estimation improvement
#8714 Deye inverter integration
#8969 Parallel string voltage deviation protection
#9153 SOC Updates
#9526 Swap SOC/UserSOC functionality
#8949 Added motorola format total voltage broadcast
#8941 Afore inverter integration
#8192 EDN Charger fix
#8625 Master-Slave ramp up current fix
#7870 Charge restart based on min cell voltage
#9100 Lion Charger CCL fix
#8094 When wire break is found some voltage calculations might not be fully correct
#8095 Wire break detection for LTO cells with higher voltages (~3.4V) is not accurate
#7485 In some situations entering L2 access (when L2 password is not set) can be complicated
2019-02-11 17:36:44
Notifications of End of Life announcement of EMUS products . For full history list of EoL notifications please press "Show all Versions" at the bottom.
Download2019-02-11 17:37:55
Notifications of EMUS products price changes. For full history list of price update notifications press "Show all Versions" at the bottom.
Download2019-10-01 08:20:57
Detailed description of G1 BMS CANopen Object Dictionary
Download2021-11-03 18:27:48
Download Release Notes2018-12-10 10:34:09
Download Release NotesOur company specialists are ready to provide technical assistance and consult in matters related with use of our products. In order to attain the best service quality, we kindly ask you to fill the contact form by clicking the button below.