Test EMUS BMS risk free!
Please refer to documentation manuals and datasheets below for our products information. All related apps, software and firmware are listed as well.
2020-12-15 12:50:29
G1 BMS system user manual which documents the whole BMS system components, connectivity, configuration, monitoring, troubleshooting and much more.
Download Release NotesAdded new chapters:
2.1.3 Centralized Cell Monitoring
2.1.4 Temperature measurement
2.3.2 Integrated SOC/SOH estimator (gen1 algorithm)
2.3.2.1 SOH algorithm
2.7 Warnings
4.1 EMUS BMS Control Panel
4.9 Charging process
4.14 SOC Estimation
4.14.1 SOC legacy adjustment algorithm
4.14.2 SOC/SOH estimator (gen1 algorithm)
4.14.2.1 Tuning parameters
4.14.2.2 Cell model reference settings
4.14.2.3 SOC-OCV dependency curve of cell
4.14.2.4 SOC dependency on temperature
Other:
All products technical information has been transferred to separate datasheet documents
2021-01-28 15:32:49
Download Release Notes2019-10-01 08:20:57
Detailed description of G1 BMS CANopen Object Dictionary
Download2018-12-10 10:31:23
Download Release Notes2018-12-10 10:34:09
Download Release Notes2021-01-05 14:07:31
Download Release NotesFixes:
Fix to discovered CGMs showing incorrect number of cells
Known issues:
Battery Charge/Capacity not recalculated/displayed in legacy firmware
PSU input/output does not function correctly
No warning/message when password is typed in incorrectly more than 10 times
Pin inversion on some pin functions
2021-03-10 18:22:58
Download Release NotesCell communication issue
SOC calculation issue
Multiple peripheral issue
Charge/Discharge/Over-Current Delay
2020-05-26 18:39:31
Download Release NotesFixes
Value of 'Total Voltage' in Layout #4 was displayed incorrectly above 655 volts
2020-03-03 14:34:49
Firmware for EMUS BMS Mini devices.
Download Release NotesFeatures
Added CANopen protocol support for Serial peripheral
Added Delta-Q charger support
Added CANopen client support
Added CiA 418 PDO support
Added pin function status report
Added power saving modes (storage - deep, automatic - light)
Added internal operational limits (current, temperature)
Added "Not detected battery" EMCY object
Added 'Storage mode' pin function
Improved battery detection mechanism
Added Current sensing configuration parameters
Fixes
Fixed repetitive toggle between charging stages
Sometimes charging was impossible until any protection recovers
Sometimes protectiosn were not triggered properly
Fixed CANopen OD 0x6000
Sometimes protection was triggered twice resulting in registering duplicated protection
When all emergency error codes are cleared BMS did not switch from pre-operational to operational state.
CANopen OD 0x1001 incorrect update
Reset to factory defaults was not working correctly
Inverting GPO pin function did not work correctly
'Protection reset' pin function could be triggered once
Fixed initial notification of not detected batteries when system starts-up
When system starts contactor pre-charge is not activated before closing contactor
2019-02-11 17:36:44
Notifications of End of Life announcement of EMUS products . For full history list of EoL notifications please press "Show all Versions" at the bottom.
Download2019-02-11 17:37:55
Notifications of EMUS products price changes. For full history list of price update notifications press "Show all Versions" at the bottom.
DownloadOur company specialists are ready to provide technical assistance and consult in matters related with use of our products. In order to attain the best service quality, we kindly ask you to fill the contact form by clicking the button below.